1、 Product Introduction
The GE IC697CPX928-CD Programmable Logic Controller (PLC) is a high-end core controller in the GE Fanuc RX3i series, designed specifically for the complex control requirements of medium to large industrial automation control systems. As the “intelligent hub” in the field of industrial control, it integrates features such as high-speed computing, multi protocol communication, flexible expansion, and high reliability. It can achieve centralized control of decentralized devices, complex logical operations, and real-time data processing, and is widely adaptable to various application scenarios from single machine automation to distributed control systems (DCS). It is a key hardware carrier in GE’s industrial automation solutions. ​
2、 Parameter specifications
Core performance: Adopting a 32-bit RISC processor, the computing speed can reach 0.08 μ s/Boolean instruction, supporting a maximum of 2MB user program memory and 4MB data memory, which can meet the storage and high-speed execution requirements of large-scale control programs. ​
Power specifications: The input voltage is AC 100-240V, 50/60Hz, and the output can provide+5V DC (3A) and+24V DC (1A) auxiliary power for the expansion module, with overvoltage, overcurrent, and short-circuit protection functions. ​
Communication capability: Integrated with 1 10/100Mbps Ethernet interface (supporting Modbus TCP/IP, EtherNet/IP protocols), 1 RS-232 serial interface (for programming and debugging), and can support various industrial buses such as Profinet and DeviceNet through extended communication modules. ​
I/O Expansion: Supports the full range of GE RX3i series I/O modules, with a maximum expansion capacity of 32 local I/O racks. Each rack can accommodate up to 16 modules, enabling flexible configuration of I/O signals such as digital, analog, and special functions (such as high-speed counting and pulse output). ​
Programming environment: Compatible with GE Proficy Machine Edition programming software, supporting international standard programming languages such as ladder diagram (LD), function block diagram (FBD), structured text (ST), sequential function diagram (SFC), etc. ​
Environment and installation: The working temperature range is 0-60 ℃, the storage temperature is -40-85 ℃, and the relative humidity is 5% -95% (no condensation); The protection level is IP20 (rack mounted state), and it is installed using standard 35mm DIN rails, supporting horizontal or vertical installation methods. ​
Redundancy and reliability: Supports dual machine hot standby redundancy configuration (with redundant modules), with an average time between failures (MTBF) of over 100000 hours, and features online program modification, breakpoint debugging, and fault self diagnosis. ​
3、 Application industry scenarios
Manufacturing industry: used for logical control and equipment linkage of welding robot workstations and painting production lines in the production of automobiles and parts, achieving precise control such as welding parameter adjustment and workpiece transmission positioning; In the field of electronic manufacturing, process control for SMT surface mount machines and reflow soldering equipment is adapted to ensure surface mount accuracy and production pace. ​
Power industry: applied to auxiliary control systems for small and medium-sized thermal power plants (such as water supply pumps, induced draft fan control), real-time monitoring of motor current, pressure, flow rate and other parameters, and equipment start stop protection through logical interlocking; In distributed photovoltaic power plants, responsible for communication coordination between inverters and combiner boxes, as well as power generation data collection and uploading. ​
Water treatment industry: In municipal sewage treatment plants, it is used for regulating dissolved oxygen in aeration tanks and controlling the operation of sludge dewatering machines. PID algorithm is used to accurately control valve opening and pump speed to ensure that the effluent quality meets the standard; In industrial wastewater treatment, automation control is adapted to processes such as acid-base neutralization and precipitation filtration. ​
Metallurgical industry: In the steel rolling production line, it is used for controlling the rolling mill pressure and synchronously adjusting the steel strip speed. The encoder signal is collected through a high-speed counting module to achieve real-time correction of steel strip tension and thickness; In non-ferrous metal smelting, responsible for the logical control of furnace temperature and ingredient ratio to ensure the stability of the smelting process. ​
Food and beverage industry: Adapt to bottled water and beverage filling production lines, control the coordinated operation of bottle washing, filling, capping and other equipment, detect the position of the bottle body through photoelectric sensors, and avoid problems such as missed filling and wrong capping; In dairy production, precise control of fermentation tank temperature and stirring speed is used to ensure product quality uniformity. ​
4、 Product positioning core functions
Complex logic control: With high-speed processors and large capacity memory, it can perform multi task parallel control, support nested subroutines, interrupt handling, and complex mathematical operations, meeting the complex control requirements of multi device linkage and process interlocking in production lines. ​
Real time data exchange: Through Ethernet and serial communication interface, bidirectional data transmission with HMI (human-machine interface), upper computer system (such as SCADA) and other intelligent devices is achieved, supporting production data collection, equipment status monitoring and remote command issuance. ​
Flexible I/O Expansion: Compatible with the full range of RX3i I/O modules, it can be configured with digital input/output, analog acquisition and control, high-speed counting, pulse output and other functions according to actual needs, adapting to signal processing scenarios in different industries. ​
Reliable operation guarantee: equipped with comprehensive fault diagnosis functions, it can monitor the status of power, communication, and I/O modules in real time, and immediately trigger alarms and execute preset protection logic when abnormalities occur; Support dual machine hot standby redundancy to ensure uninterrupted operation of critical systems. ​
Convenient programming and debugging: Based on the Proficy Machine Edition software platform, it supports graphical programming and online debugging, enabling program breakpoint running, real-time variable monitoring, and online modification, reducing development and maintenance difficulties. ​
5、 Technical Characteristics and Advantages
High performance computing: The 32-bit RISC processor is paired with an optimized instruction set, and the Boolean instruction processing speed is only 0.08 μ s, far exceeding the performance of PLCs of the same level. It can quickly respond to the control requirements of complex processes and avoid production deviations caused by computing delays. ​
Multi protocol compatibility: natively supports mainstream industrial Ethernet protocols such as Modbus TCP/IP and EtherNet/IP, and can be adapted to buses such as Profinet and DeviceNet through expansion modules, easily achieving interconnection and interoperability with different brands of devices (such as frequency converters, sensors, robots), reducing the difficulty of system integration. ​
High reliability design: using industrial grade components and redundant power supply configuration, MTBF exceeds 100000 hours, and can withstand electromagnetic interference, voltage fluctuations, and temperature changes in harsh industrial environments; Support automatic backup and recovery of programs to reduce unexpected downtime losses. ​
Flexible expansion capability: Up to 32 local I/O racks can be expanded, supporting mixed configurations of digital, analog, and special function modules. Modules can be flexibly added according to production scale expansion or process upgrades, without the need to replace core controllers, reducing later upgrade costs. ​
Intelligent integration: it can access the GE Proficy industrial Internet platform, realize cloud storage and analysis of production data, support intelligent applications such as predictive maintenance and energy optimization, and help enterprises transform from “automation” to “intelligence”. ​
6、 Installation and maintenance
Installation specifications:
Before installation, it is necessary to confirm that the power supply voltage matches the equipment specifications. The rack installation position should be far away from strong electromagnetic interference sources (such as frequency converters, high-power motors) and heat sources (such as heaters, radiators), and at least 10cm of heat dissipation space should be reserved. ​
Using 35mm DIN rail to fix the rack, ensuring a secure installation without shaking; When wiring, it is necessary to distinguish between power and signal cables to avoid parallel laying of strong and weak electrical cables. The wiring terminals should be tightened to prevent poor contact. ​
Programming communication cables require the use of shielded cables, with the shielding layer grounded at one end to reduce communication interference; After installation, insulation testing is required to ensure that the circuit insulation resistance meets industrial safety standards. ​
Daily maintenance:
Regularly (monthly) check the status of power indicator lights and communication indicator lights, view module fault logs through programming software, and promptly identify potential problems; Clean the surface dust of racks and modules quarterly, using dry compressed air or soft bristled brushes to avoid dust accumulation affecting heat dissipation. ​
Regularly (every six months) check the tightness of the wiring terminals, especially the power and communication cable joints, to prevent loosening caused by vibration; Backup user programs and system configurations, store them on secure media to prevent program loss. ​
When handling faults, priority should be given to locating the fault point through module indicator lights and diagnostic logs. Before replacing the module, the power supply should be disconnected and anti-static measures should be taken; If it involves program modification, the original program needs to be backed up first, and after modification, offline testing should be conducted before going online for operation. ​
7、 Related product introduction
GE RX3i Series Supporting Modules:
Digital I/O modules, such as IC697MDL645 (32 point digital input) and IC697MDL753 (32 point digital output), are suitable for the acquisition and control of digital signals such as switches and contactors. ​
Analog I/O modules, such as IC697ALG223 (4-channel analog input) and IC697ALO260 (4-channel analog output), are used for precise acquisition and adjustment of analog signals such as temperature, pressure, and flow rate. ​
Communication expansion modules, such as IC697CMM742 (Profinet communication module) and IC697CMM743 (DeviceNet communication module), enhance the bus communication capability of the controller. ​
Special function modules: such as IC697HSC302 (high-speed counting module), IC697PNS201 (pulse output module), suitable for special application scenarios such as high-speed positioning and motion control. ​
GE Industrial Automation Supporting Products:
HMI human-machine interface: such as Proficy iFIX configuration software and PanelView Plus touch screen, can seamlessly integrate with IC697CPX928-CD to achieve visual monitoring and manual operation of production processes. ​
Frequency converter and motor: For example, the PowerFlex 755 series frequency converter is linked with PLC through communication protocol to achieve precise adjustment of motor speed and energy-saving control. ​
Industrial Internet platform: Proficy Predix platform, which can access the production data collected by PLC, provide intelligent services such as equipment health management and energy consumption analysis, and help enterprises transform digitally.

Main products
BRAND
DCS system Foxboro CPU (CP InItIo) such as CP100, CP30, CP40, CP60, CP71, CP99, etc
CARD (FBM InItIo) such as FBM01, FBM02, FBM09, FBM12, FBM44, FBM201, FBM209, FBM242, FBMSVH, etc
CPU (FCP InItIo) such as FCP270, FCP280, etc
POWER (IPM InItIo) such as IPM02-P0904HA, etc
anti-static
TRICONEX
Schneider modules such as 3006, 3007, 3008, 3009, 3101 DI3301、AI3351、DO3401、3604E、3664、3700A、3721、3625、4119A、4351B、3625、4355X、3503E、3805E、3503E、 8111, 8312, etc
Emerson ovatIon module (IC InItIo), such as: 1 C311224G01、1C311227G01、1C311234G01、1C311238H01、1C311194G01、1C311197G01 wait
Modules (IX InItIo) such as 1X00416H01, 1X00024H01, 5X00167G01, 5X00497G01, etc
Modules (KJ InItIo) such as KJ3203X1-BA1, KJ3001X1-BB1, etc
ABB
Pelé
(IM InItIo) such as IMHSS03, IMASI23, IMDSO14, IMRDI13, etc
(Initialization) such as INICT01, etc
(BRC InItIo) such as BRC300, etc
Yokogawa (CP) such as CP345, CP451, CP703, etc
(Initial of PW) such as PW301, PW302, PW481, etc
(AIP InItIo) such as AIP578, AIP552, etc
(AMM InItIo) such as AMM12, AMM22, AMM42, etc
(ADM InItIo) such as ADM11, ADM52, ADM55, etc
Honeywell (TC InItIo) such as TC-pr-021, TC-ccr014, etc
(TK InItIo) such as TK-pr-021, TK-ppd011, etc
(CC InItIo) such as CC-panon01, CC-tax11, CC-paox01, etc
(51 poems written) such as 51195156-300, 51195156-200, etc
Moore modules such as MBI/MNI (16413-15), QLCCM, QLCDM, 39SDM, 39HFM, 39ACM, 1610H74, 16114-171, etc
PLC systems a-b
rockwell
ICS three-way multiplexing (1756 InItIo), such as 1756- l61、1756-l62、1756-l71、1756-l55m12、1756-l40b、1756-l60b、1756-enbt、1756-rm wait
(1757 at the beginning), such as 1757 SRM, etc
(1785 InItIo) such as 1785-l20b, 1785-l350b, etc
(1771 InItIo) such as 1771 Ian, 1771 obn, etc
(1746 InItIo) such as 1746-nt8, etc
For example: 1747-nI16I, 1747-L541, 1747-L542, 1747-L551, 1747-L552, 1747-L553, etc
(2711P InItIo) such as 2711P-k7c4d1, 2711P-t6c5a, etc
For example: T8311, T8451, T8461, T8403, T810B, etc
RelIance (57C InItIo), such as 57C404C, 57C424, etc
(MD InItIo) such as MD-b6027c, etc
(S InItIo) such as S-d4008-e, etc
(WR InItIo) such as WR-d4006-a, etc
(0 InItIo) For example: 0-60002-6, etc
Schneider (140 InItIo) such as: 140 CPU65150、140CPU67160、140CPU11302、140CPU43412A、140CPU31110、140CPU67861、140CRA93200、140NOE77101、140DDI84100 wait
For example: 170INT11003, 170PNT11020, etc
(AS InItIo) such as AS-b840-108, AS-p892-2000, etc
(PC InItIo) such as PC-a984-130, etc
GE (IC693 InItIo) such as IC693CPU374, IC693CPU360, etc
(IC697 InItIo) such as IC697CPX772, IC697CPX928, IC697ALG320, IC697CPX935, IC697BEM711, etc
(IC698 InItIo) such as IC698CPE020, IC698CPE030, IC698CRE040, IC698CPE040, etc
(IC660 InItIo) such as IC660ELB912, IC660BBD025, etc
(IS200 InItIo) such as IS200STCIH2A, IS200TTURH1CFD, IS200TVBAH2ACC, etc
For example: IS220PAICH1A, IS220PAICH2A, IS220PPROS1B, IS220PDIAH1B, etc
(DS200 InItIo) such as DS200ADGIH1AAA, DS200FSAAG2ABA, DS200DCFBG1BJB, DS200LDCCH1AGA, etc
(SR489 InItIo) such as SR489-p5-hI-a20-e, etc
(SR469 InItIo) such as SR469-p5-hI-a20, SR469-p5-hI-a20-e, etc
(VMIVME InItIo) such as: VMIVME-7750, VMIVME-7807, VMIVME-7700, VMIVMME-4140, VMIVMME-2510b, etc
(SR InItIo) such as: SR469-P5-HI-A20、SR369-369-HI-RM-0-0-0、SR489-P5-HI-A20-E、SR750-p5-g5-d5-hI-a20-r wait
For example: 3500/15, 3500/20, 3500/22m, 3500/42m, 3500/25, 3500/32, etc
(3300 initialization) such as 3300/16-14-01-03-00-01, 3300/20-12-01-03-00-00, etc
(1900 InItIo) such as 1900/65a, 1900/65a-01-01-00-00, etc
(MVMEInItiIo) such as: MVME147-013,MVME162-012,MVME2301-900,MVME167-33B,MVME172-263/260,MVME5100,MVME5100 MVME712A/AM、MVME147SRF MVME2100,VMVE172PA652SE,MVME5500, Wait
XYCOM module (XVME InItIo), such as XVME-530, XVME-976, XVME-653, XVME-244, etc
WestInghouse (5X InItIo) such as 5X00170G01, 5X00605G01, etc
(1C311 initialization) For example: 1C31132G01, 1C31161G02, 1C31116G04, 1C31194G01, 1C31166G01, etc
NI (SCXI InItIo) such as SCXI-1104c, SCXI-1000, SCXI-1100, SCXI-1102, SCXI-1126, PXI-8186, etc
(PC InItIo) such as PCI-8517, PCI-6224, CFP-AI-111, etc

additional information

product reviews

Reviews

There are no reviews yet.

Be the first to review “GE IC697CPX928-CD Programmable Logic Controller”

Your email address will not be published. Required fields are marked *