PFV1 401, ID: 3BSE018732R1 Controller

Warranty: 365 days
Quality: Original module
Condition: New / Used
Warehouse: Spot
Delivery time: Shipped in 3 days after payment
WhatsApp:+86 18030183032
Mailbox:3248602330@qq.com

  • 100% original product WeChat: 18301830183032

  • After sales guarantee WhatsAPP:+8618030183032
  • Quick ordering Email:3248602330@qq.com

product description

3BSE018732R1 (PFV1 401) Controller
3BSE018732R1 is a controller under the ABB brand that is positioned for industrial automation control scenarios. The “PFV1 401” in its product label is the core specification code for this model of controller, mainly used in medium and high voltage power systems, industrial transmission equipment, or large-scale process control fields, undertaking key tasks such as logic operation, signal processing, and equipment collaborative control.
1、 Core Basic Information
Specific project content
Brand and affiliation: ABB (a globally leading industrial automation and power technology enterprise, this controller belongs to its industrial control product line)
Model identification order number: 3BSE018732R1; Specification code: PFV1 401
Product positioning: High voltage system dedicated controller, focusing on “control accuracy” and “high reliability”, suitable for harsh industrial environments
Typical application scenario 1. Core control of medium and high voltage frequency converters/soft starters;
2. Control of reactive power compensation and harmonic control equipment in the power system;
3. Transmission control logic units for large industrial machinery such as rolling mills, fans, and water pumps
2、 Key technical characteristics
1. Control performance
Multi signal processing capability: supports synchronous acquisition and processing of analog signals (such as current and voltage signals) and digital signals (switch signals), with a high sampling frequency (usually up to kHz level), ensuring real-time monitoring of the status of the controlled equipment.
Logical operations and algorithm support: Built in industrial grade control algorithms (such as PID regulation, logic interlocking, sequence control), customizable control logic according to on-site requirements, and adaptable to dynamic adjustments under complex working conditions.
2. Reliability design
Environmental adaptability: It has a wide temperature working range (usually -25 ℃~+70 ℃) and supports dust and moisture protection design (some scenarios can be equipped with IP20 or above protective enclosures), adapting to harsh environments in industrial sites.
Redundancy and Fault Tolerance: Some configurations support redundant acquisition of critical signals or double checking of control instructions, reducing the risk of system downtime caused by single point failures and meeting the reliability requirements of continuous production scenarios.
3. Communication and compatibility
Communication interface: usually integrated with industrial Ethernet (such as Ethernet/IP, Profinet), serial port (RS485/RS232) or ABB dedicated bus (such as Profibus DP), can communicate with upper computer (such as SCADA system PLC)、 Seamless data exchange between on-site sensors/actuators.
System compatibility: Suitable for ABB’s medium and high voltage transmission systems (such as ACS series frequency converters), process control systems (such as 800xA systems), and can also be compatible with third-party industrial automation equipment through standardized protocols to reduce system integration difficulty.
3、 Installation and usage precautions
Installation environment requirements: It should be installed in a well ventilated, non corrosive gas, and non strong electromagnetic interference control cabinet, avoiding direct contact with high-temperature heat sources (such as power modules), and ensuring that the controller’s operating temperature is stable within the rated range.
Wiring specifications: Strictly follow the wiring diagram in the product manual for the connection of power and signal cables, paying special attention to the shielding treatment of analog signals (it is recommended to use shielded cables with single ended grounding), to prevent signal interference from causing a decrease in control accuracy.
Parameter configuration: The control parameters of the controller (such as PID gain, sampling period, interlock logic) need to be configured through ABB dedicated programming software (such as Control Builder M) or debugging tools. Before configuration, the process requirements of the controlled equipment need to be clearly defined to avoid parameter mismatch and system abnormalities.
Maintenance and Overhaul: Regularly check the power supply voltage and communication link status of the controller. If a fault code appears (which can be viewed through the controller panel indicator light or upper computer alarm information), refer to the troubleshooting manual to locate the problem (such as loose cables, interface faults, parameter errors, etc.), to avoid blind disassembly and hardware damage.

 

Main products
BRAND
DCS system Foxboro CPU (CP InItIo) such as CP100, CP30, CP40, CP60, CP71, CP99, etc
CARD (FBM InItIo) such as FBM01, FBM02, FBM09, FBM12, FBM44, FBM201, FBM209, FBM242, FBMSVH, etc
CPU (FCP InItIo) such as FCP270, FCP280, etc
POWER (IPM InItIo) such as IPM02-P0904HA, etc
anti-static
TRICONEX
Schneider modules such as 3006, 3007, 3008, 3009, 3101 DI3301、AI3351、DO3401、3604E、3664、3700A、3721、3625、4119A、4351B、3625、4355X、3503E、3805E、3503E、 8111, 8312, etc
Emerson ovatIon module (IC InItIo), such as: 1 C311224G01、1C311227G01、1C311234G01、1C311238H01、1C311194G01、1C311197G01 wait
Modules (IX InItIo) such as 1X00416H01, 1X00024H01, 5X00167G01, 5X00497G01, etc
Modules (KJ InItIo) such as KJ3203X1-BA1, KJ3001X1-BB1, etc
ABB
Pelé
(IM InItIo) such as IMHSS03, IMASI23, IMDSO14, IMRDI13, etc
(Initialization) such as INICT01, etc
(BRC InItIo) such as BRC300, etc
Yokogawa (CP) such as CP345, CP451, CP703, etc
(Initial of PW) such as PW301, PW302, PW481, etc
(AIP InItIo) such as AIP578, AIP552, etc
(AMM InItIo) such as AMM12, AMM22, AMM42, etc
(ADM InItIo) such as ADM11, ADM52, ADM55, etc
Honeywell (TC InItIo) such as TC-pr-021, TC-ccr014, etc
(TK InItIo) such as TK-pr-021, TK-ppd011, etc
(CC InItIo) such as CC-panon01, CC-tax11, CC-paox01, etc
(51 poems written) such as 51195156-300, 51195156-200, etc
Moore modules such as MBI/MNI (16413-15), QLCCM, QLCDM, 39SDM, 39HFM, 39ACM, 1610H74, 16114-171, etc
PLC systems a-b
rockwell
ICS three-way multiplexing (1756 InItIo), such as 1756- l61、1756-l62、1756-l71、1756-l55m12、1756-l40b、1756-l60b、1756-enbt、1756-rm wait
(1757 at the beginning), such as 1757 SRM, etc
(1785 InItIo) such as 1785-l20b, 1785-l350b, etc
(1771 InItIo) such as 1771 Ian, 1771 obn, etc
(1746 InItIo) such as 1746-nt8, etc
For example: 1747-nI16I, 1747-L541, 1747-L542, 1747-L551, 1747-L552, 1747-L553, etc
(2711P InItIo) such as 2711P-k7c4d1, 2711P-t6c5a, etc
For example: T8311, T8451, T8461, T8403, T810B, etc
RelIance (57C InItIo), such as 57C404C, 57C424, etc
(MD InItIo) such as MD-b6027c, etc
(S InItIo) such as S-d4008-e, etc
(WR InItIo) such as WR-d4006-a, etc
(0 InItIo) For example: 0-60002-6, etc
Schneider (140 InItIo) such as: 140 CPU65150、140CPU67160、140CPU11302、140CPU43412A、140CPU31110、140CPU67861、140CRA93200、140NOE77101、140DDI84100 wait
For example: 170INT11003, 170PNT11020, etc
(AS InItIo) such as AS-b840-108, AS-p892-2000, etc
(PC InItIo) such as PC-a984-130, etc
GE (IC693 InItIo) such as IC693CPU374, IC693CPU360, etc
(IC697 InItIo) such as IC697CPX772, IC697CPX928, IC697ALG320, IC697CPX935, IC697BEM711, etc
(IC698 InItIo) such as IC698CPE020, IC698CPE030, IC698CRE040, IC698CPE040, etc
(IC660 InItIo) such as IC660ELB912, IC660BBD025, etc
(IS200 InItIo) such as IS200STCIH2A, IS200TTURH1CFD, IS200TVBAH2ACC, etc
For example: IS220PAICH1A, IS220PAICH2A, IS220PPROS1B, IS220PDIAH1B, etc
(DS200 InItIo) such as DS200ADGIH1AAA, DS200FSAAG2ABA, DS200DCFBG1BJB, DS200LDCCH1AGA, etc
(SR489 InItIo) such as SR489-p5-hI-a20-e, etc
(SR469 InItIo) such as SR469-p5-hI-a20, SR469-p5-hI-a20-e, etc
(VMIVME InItIo) such as: VMIVME-7750, VMIVME-7807, VMIVME-7700, VMIVMME-4140, VMIVMME-2510b, etc
(SR InItIo) such as: SR469-P5-HI-A20、SR369-369-HI-RM-0-0-0、SR489-P5-HI-A20-E、SR750-p5-g5-d5-hI-a20-r wait
For example: 3500/15, 3500/20, 3500/22m, 3500/42m, 3500/25, 3500/32, etc
(3300 initialization) such as 3300/16-14-01-03-00-01, 3300/20-12-01-03-00-00, etc
(1900 InItIo) such as 1900/65a, 1900/65a-01-01-00-00, etc
(MVMEInItiIo) such as: MVME147-013,MVME162-012,MVME2301-900,MVME167-33B,MVME172-263/260,MVME5100,MVME5100 MVME712A/AM、MVME147SRF MVME2100,VMVE172PA652SE,MVME5500, Wait
XYCOM module (XVME InItIo), such as XVME-530, XVME-976, XVME-653, XVME-244, etc
WestInghouse (5X InItIo) such as 5X00170G01, 5X00605G01, etc
(1C311 initialization) For example: 1C31132G01, 1C31161G02, 1C31116G04, 1C31194G01, 1C31166G01, etc
NI (SCXI InItIo) such as SCXI-1104c, SCXI-1000, SCXI-1100, SCXI-1102, SCXI-1126, PXI-8186, etc
(PC InItIo) such as PCI-8517, PCI-6224, CFP-AI-111, etc

additional information

product reviews

Reviews

There are no reviews yet.

Be the first to review “PFV1 401, ID: 3BSE018732R1 Controller”